Logo

Cart

Click title to display cart contents.
0 Items $0.00

Suzuki VZ800, VZR1800 1997-2008 Factory Service & Shop Manual

Catalog: 

Make: 

Model: 

US Dollar: $12.99

Complete workshop & service manual with electrical wiring diagrams for 1997-2008 Suzuki VZ800V, VZ800W, VZ800X, VZ800Y, VZ800K1, VZ800K2, VZ800K5, VZR1800K6, VZR1800K7, VZR1800K8. It's the same service manual used by dealers that guaranteed to be fully functional and intact without any missing page.

This Suzuki VZ800, VZR1800 Motorcycle service & repair manual (including maintenance, overhaul, disassembling & assembling, adjustment, tune-up, operation, inspecting, diagnostic & troubleshooting…) is divided into different sections. Each section covers a specific component or system with detailed illustrations. A table of contents is placed at the beginning of each section. Pages are easily found by category, and each page is expandable for great detail. The printer-ready PDF documents work like a charm on all kinds of devices.

“VZ800.pdf”
MAKE: Suzuki
MODEL: VZ800 (VZ800V, VZ800W, VZ800X, VZ800Y, VZ800K1, VZ800K2)
YEAR: 1997, 1998, 1999, 2000, 2001, 2002
PAGES: 314

“'05 VZ800.pdf”
MAKE: Suzuki
MODEL: VZ800 (aka Boulevard M50)
YEAR: 2005
PAGES: 454

“'06-'08 VZR1800.pdf”
MAKE: Suzuki
MODEL: VZR1800 (K6, K7, K8)
YEAR: 2006 2007 2008
PAGES: 588

EXCERPT:
EXCVA ADJUSTMENT 1st step:
• Set the EXCVA to adjustment position. (!7-2)
• Make sure that the No. 2 cable and No. 1 cable are fixed into the clamp.
2nd step:
• Turn the mode select switch OFF.
• Turn the ignition switch ON to check the EXCVA operation.
• Turn the mode select switch ON.
• If C46 is not indicated on the LCD (DISPLAY), the adjustment
is correctly completed. In this case, it is unnecessary to pro-
ceed to 3rd step.
• If C46 is indicated, repeat the adjustment procedure from 3rd
and 4th step.
ON OFF
3rd step:
• This procedure is only required when C46 is indicated.
• Turn the ignition switch OFF.
• Remove the lower frame cover. (!7-8)
• Insert the two copper wires into the back side of the position
sensor lead wire coupler 1.
• Disconnect the EXCVA motor lead wire coupler 2.