Complete workshop & service manual with electrical wiring diagrams for Komatsu Hydraulic Excavator PC210LC-10. It's the same service manual used by dealers that guaranteed to be fully functional and intact without any missing page.

This Komatsu Hydraulic Excavator PC210LC-10 service & repair manual (including maintenance, overhaul, disassembling & assembling, adjustment, tune-up, operation, inspecting, diagnostic & troubleshooting…) is divided into different sections. Each section covers a specific component or system with detailed illustrations. A table of contents is placed at the beginning of each section. Pages are easily found by category, and each page is expandable for great detail. The printer-ready PDF documents work like a charm on all kinds of devices.

FILELIST:
CEAM026500 - Hydraulic Excavator PC210LC-10 Operation & Maintenance Manual.pdf
CEBM026702 - Hydraulic Excavator PC210LC-10 Shop Manual.pdf
SEN05842-01 - Hydraulic Excavator PC210LC-10 Shop Manual.pdf

EXCERPT:
50 Disassembly and assembly
Engine and cooling system
Removal and installation of fuel cooler assembly (PC220-B7W0-924-K-00-A)
If the fuel is too much, drain the fuel in order to stop the fuel flow from the fuel tank return hose.
Removal (PC200_10-B7W0-520-K-00-A)
1. Open the left side cover and remove plate (1).
2. Disconnect hose clamps (2).
3. Disconnect two hoses (3). [*1]
Make sure to hold elbow (L) on the fuel cooler by using another spanner while disconnecting the hoses to avoid stressing the cooler.
If a spanner is not used, stress will be applied to the cooler and the welded portions (M) may come apart.
4. Remove fuel cooler mounting bolts (4).
5. Remove fuel cooler (5).
Installation (PC200_10-B7W0-720-K-00-A)
Perform installation in the reverse order to removal.
[*1]
Make sure to hold elbow (L) on the fuel cooler by using another spanner while connecting the hoses to avoid stressing the cooler.
If a spanner is not used, stress will be applied to the cooler and the welded portions (M) may come apart.
...