Complete digital official shop manual contains service, maintenance, and troubleshooting information for the Infiniti G25 (V36) 2011-2012. Diagnostic and repair procedures are covered in great detail to repair, maintain, rebuild, refurbish or restore your vehicle like a professional mechanic in local service/repair workshop. This cost-effective quality manual is 100% complete and intact as should be without any missing pages. It is the same factory shop manual used by dealers that guaranteed to be fully functional to save your precious time.

This manual for Infiniti G25 (V36) 2011-2012 is divided into different sections. Each section covers a specific component or system and, in addition to the standard service procedures, includes disassembling, inspecting, and assembling instructions. A table of contents is placed at the beginning of each section. Pages are easily found by category, and each page is expandable for great detail. It is in the cross-platform PDF document format so that it works like a charm on all kinds of devices. You do not need to be skilled with a computer to use the manual.

EXCERPT:
2012 Infiniti G25 Journey
2012 ENGINE Engine Mechanical (VQ37VHR) - G Sedan
BASIC INSPECTION
CAMSHAFT VALVE CLEARANCE
Inspection and Adjustment
INSPECTION
Check valve clearance if applicable to the following cases:
Intake side:
At the removal and installation of VVEL ladder assembly or valve-related parts, or at the occurrence of malfunction (poor starting, idle malfunction, unusual noise) due to aged deterioration in valve clearance.
CAUTION: Valve clearance check on the intake side is not required after replacing the VVEL ladder assembly and cylinder head assembly with a new one. (Install new VVEL ladder assembly and cylinder head assembly in factory-shipped condition because it is factory-adjusted and inspected.)
NOTE: VVEL ladder assembly cannot be replaced as a single part, because it is machined together with cylinder head assembly.
Exhaust side:
At the removal, installation, and replacement of camshaft (EXH) or valve-related parts, or at the occurrence of malfunction (poor starting, idle malfunction, unusual noise) due to aged deterioration in valve clearance.
1. Remove rocker covers (bank 1 and bank 2). Refer to "REMOVAL AND INSTALLATION".
2. Measure the valve clearance as follows:
Use the feeler gauge (commercial service tool) of curved-tip. This allows the feeler gauge to access the clearance between camshaft and valve lifter with ease.
Valve clearance: Refer to "CAMSHAFT".
Before measuring, check that the position of drive shaft nose is within the angle shown in the figure.
Fig. 7: Measuring Valve Clearance
Refer to the illustration for the insertion direction of the feeler gauge since the direction depends on the bank.
a. Set No. 1 cylinder at TDC of its compression stroke.
Rotate crankshaft pulley clockwise to align timing mark (grooved line without color) with timing indicator.
Fig. 8: Locating Timing Mark (Grooved Line Without Color)
Check that exhaust cam nose on No. 1 cylinder (engine front side of bank 1) is located as shown in the figure.
Fig. 9: Identifying Exhaust Cam Nose On No. 1 Cylinder (Engine Front Side Of Bank 1)
If not, turn crankshaft one revolution (360 degrees) and align as shown in the figure.
By referring to the figure, measure the valve clearances at locations marked "x" as shown in the table below (locations indicated in the figure).
...